RedBox (2-rail conductor)

> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product selection: RedBox DCC

description file edition
Digital-current ring conductor with multiple supply connection (with DB-2) page_1842 09/2020
Digital-current ring conductor with multiple supply connection (with DB-4) page_1843 09/2020
External supply to the Decoder page_329 07/2020
Correct connection of the external supply voltage page_506 07/2020
Seperate digital-current conductor for the decoder (with DB-2) page_1844 09/2020
Seperate digital-current conductor for the decoder (with DB-4) page_1845 09/2020
Ring conductor to the decoder page_003 07/2020
Suppression of interferences caused by end-off switched turnouts page_330 07/2020
PIKO A-rail drive switched via resistor page_331 07/2020
Supply to monitored track sections (track occupancy feedback) (with DB-2) / patch-cable to s88-N page_1846 04/2020
Supply to monitored track sections (track occupancy feedback) (with DB-4) / patch-cable to s88-N page_1847 04/2020
Track occupancy feedback with one isolated rail (with DB-2) / patch-cable to s88-N page_1848 04/2020
Track occupancy feedback with one isolated rail (with DB-4) / patch-cable to s88-N page_1849 04/2020
Track occupancy feedback with two isolated rails (with DB-2) / patch-cable to s88-N page_1850 04/2020
Track occupancy feedback with two isolated rails (with DB-4) / patch-cable to s88-N page_1851 04/2020
Track monitoring with two booster current circuits (with DB-2) / patch-cable to s88-N page_1852 04/2020
Track monitoring with two booster current circuits (with DB-4) / patch-cable to s88-N page_1853 04/2020
Track section monitoring and switching off (voltage free) page_592 03/2022
Monitoring of slow-down and stop-sections and common switching off (voltage free) page_614 03/2022
Equivalent current at monitored and non-monitored areas page_615 04/2020
Reed contacts for feedback (Standard) (with DB-2) / patch-cable to s88-N page_1854 09/2020
Reed contacts for feedback (Standard) (with DB-4) / patch-cable to s88-N page_1855 09/2020
Reed contacts for feedback (Opto) (with DB-2) / patch-cable to s88-N page_1856 09/2020
Reed contacts for feedback (Opto) (with DB-4) / patch-cable to s88-N page_1857 09/2020
Driving and switching with RedBox / feedback with HSI-88 page_1823 05/2020
Accelerated feedback via HSI-88 (with DB-2) / patch-cable to s88-N page_1858 09/2020
Accelerated feedback via HSI-88 (with DB-4) / patch-cable to s88-N page_1859 09/2020
Driving and switching with RedBox / feedback with HSI-88-USB page_1828 05/2020
Accelerated feedback via HSI-88-USB (with DB-2) / patch-cable to s88-N page_1860 09/2020
Accelerated feedback via HSI-88-USB (with DB-4) / patch-cable to s88-N page_1861 09/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_1829 04/2020
Numbering the feedback registrations (various feedback modules) / patch-cable to s88-N page_1830 04/2020
Numbering the feedback modules / patch-cable to s88-N page_1831 09/2020
Numbering the feedback modules page_1832 09/2020
Data switch DSW-88-N on RedBox (various feedback modules) page_1833 05/2020
Data switch DSW-88-N on RedBox (RM-88-N-O) page_1834 05/2020
Connecting the DigitalBooster DB-2 via 5-poles booster bus page_1862 06/2020
Connecting the DigitalBooster DB-2 via Adapter Adap-CDE page_1863 06/2020
Connecting the DigitalBooster DB-4 via 5-poles booster bus page_1864 06/2020
Connecting the DigitalBooster DB-4 via CDE-booster bus page_1865 06/2020
WatchDog decoder WD-DEC with RedBox and DigitalBooster DB-2 page_1839 03/2020
GBS-DEC-DC/MM: external switchboard panel PC-controlled and RedBox page_1840 03/2020
GBS-DEC-DC/MM: s88-feedback bus branching via Data switch DSW-88-N with RedBox page_1841 03/2020

Subject to technical changes and errors.
© 2022 by LDT
Märklin and Motorola are registered trade marks.