 +====== RM-88-N-O ======
  
 +=== 16-fold Feedback Module with galvanic separated Opto-coupling-Inputs ===
 +
 +**for the s88-feedback bus for s88-standard connections and RJ-45 sockets in accordance to {{:de:cad:s88n_250.gif?50x34}}from the Digital-Professional-Serie !**
 +
 +{{  :de:foto:rm-88-n-o_10_01.jpg?  }}
 +
 +==== The feedback module RM-88-N-O is suitable for s88-standard connections with 6-poles pin bars and for bus-connections according to s88-N equipped with screened RJ-45 sockets. ====
 +
 +====== Features of the RM-88-N-O ======
 +
 +For the connection to **command stations** and **interfaces**, which supports the **s88-feedback bus**: e.g.
 +    * **Märklin Interface** (up to 31 units),
 +    * **Märklin Memory** (up to 3 units),
 +    * **Central Station 1** and **2** (up to 31 units),
 +    * **Central Station 3 plus** (up to 31 units),
 +    * **Central Station 3 via L88 (60883)** (up to 31 units per Bus 1 to 3),
 +    * **Intellibox**/**TWIN-CENTER** (up to 31 units),
 +    * **EasyControl** (up to 31 units),
 +    * **ECoS** (up to 31 units),
 +    * **Commander** (up to 31 units),
 +    * **HSI-88(-USB)** (up to 31 units) und
 +    * **DiCoStation** (up to 31 units).
 +The feedback module **RM-88-N-O** contains **16 opto-coupling-inputs** for the **potential separation** and **high interference protection**.
 +
 +**Simple and safe connection** of switch rails, contact rails, occupancy sensors and reed contacts etc. via **screw clamps**.
 +
 +The feedback module **RM-88-N-O **is suitable for **s88-standard connections** with **6-poles pin bars** and for **bus connections according to s88-N** equipped with **screened RJ-45 sockets**. It is suitable for 5 and 12V bus voltage.
 +
 +|**{{:de:cad:s88n_250.gif?101x68}}**  ^  \\ Additional information about the **standard s88-N** which will be supported by other \\ manufacturers as well can be found here: [[http://www.s88-N.eu|http://www.s88-N.eu]]. \\  {{:de:images:blindgif.gif?500x1}}  |
 +
 +If the **screening** of the **bus connections in accordance to s88-N** requires a connection to the **layout ground** is it possible to **solder** a grounded cable to the **metal housing of a RJ-45 socket**.
 +
 +{{  :de:cad:rm88no-g.gif?435x136  }}
 +
 +     * The feedback module **RM-88-N-N** can be **combined** as required with the feedback module **RM-88-N**, **RM-GB-8-N** and **RM-DEC-88** / **RM-DEC-88-O** / **RM-GB-8** with the **s88-feedback module** from **Märklin** and other suppliers.
 +     * The unit is available as ready to use **finished module**, as **finished module in a case** or as **kit** on a 86x76 mm printed circuit board with four fastening bores. (an empty case LDT-01 for kits and suitable assembly material can be found under [[:en:zubehoer#mon-set|Accessory]]).
 +     * The feedback module **RM-88-N-O** from the **Digital-Professional-Series** can be operated without any problem on your digital controlled layout because it is **100% compatible** to the s88-feedback bus.
 +     * The finished module and the finished module in a case comes with **24 month warranty**.
 +    * Each feedback module **RM-88-N-O** will be supplied with a detailed **operating-/respectively assembly-instruction**. Those instructions can be found within the next section.
 +    * You can purchase the feedback module as a **kit (-B)**, as tested **finished module (-F)** or as tested **finished module in a case (-G)**.
 +
 +====== Downloads ======
 +
 +Instructions regarding this article can be found here: [[:en:dl_rm_88_n-o|Downloads RM-88-N-O]].\\
 +Instructions for all LDT-Components can be found here: [[:en:downloads|Overview Downloads]].
 +
 +====== Sample-Connections ======
 +
 +Sample-connections regarding this article can be found here:\\
 +[[:en:ab_rm_88_n_o_3lg|Sample-Connection RM-88-N-O (3-rail conductor)]] und\\
 +[[:en:ab_rm_88_n_o_2lg|Sample-Connection RM-88-N-O (2-rail conductor)]]. \\  
 +Sample-connections for all LDT-Components can be found here: [[:en:anschlussbeispiele|Overview Sample-Connections]].\\
 +{{  :de:cad:page_668.gif  }}
 +
 +====== Add to Wish List / Prices ======
 +
 +**Attention: Products can only be added to the Wish List, if you are registered as customer at the LDT WebShop or if you are initially registered by interest of our products.**
 +
 +^{{:de:images:noticelist_m.png}} | \\  <html>Add to <b><u class="linkit" onclick="toNoticeList('310101');">Wish List</u></b></html>: **RM-88-N-O-B (Part-No.: 310101):  16-fold Feedback Module with opto-coupling-inputs**\\ as a **kit** (**39,90 €***).\\ <html>Add to <b><u class="linkit" onclick="toNoticeList('310102');">Wish List</u></b></html>: **RM-88-N-O-F (Part-No.: 310102): 16-fold Feedback Module with opto-coupling-inputs**\\ as a **finished module** (**49,90 €***).\\ <html>Add to <b><u class="linkit" onclick="toNoticeList('310103');">Wish List</u></b></html>: **RM-88-N-O-G (Part-No.: 310103): 16-fold Feedback Module with opto-coupling-inputs**\\ as a **finished module in a case** (**53,30 €***).\\ {{:de:images:blindgif.gif?580x1}} \\  ** * All prices incl. VAT, plus Shipping.**  |
 +
 +----
 +\\ 
 +====== To assure a good connection: s88-Bus Cable! ======
 +
 +The **feedback module RM-88-N-O** will be **supplied without s88-bus cable**. **Please select** a **suitable bus cable** (length and style) at the following table. For the **s88-standard connection** we supply an **interference protected, twisted** s88-bus cable with **original s88-plugs** at **length of 0,5m, 1m and 2m**. **s88-standard connections** are always required for the **connection** of the **first feedback module** to the **command station** or **interface**.
 +
 +We offer for **s88-bus connections in accordance to {{:de:cad:s88n_250.gif?50x34}} a blue screened patch cable with RJ-45 plugs at four different length of 0,5 to 3m**.
 +
 +The feedback module **RM-88-N, RM-88-N-O and RM-GB-8-N** can be connected between each other either via **s88-standard connection "Kabel s88"** or via **"Kabel Patch"** according to**{{:de:cad:s88n_250.gif?50x34}}**.
 +
 +^**s88-standard connection with 2 original s88-plugs, gray cable, twisted, round. Plus pin bar for bus extension.**|
 +|[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 0,5m]]  |
 +|[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 1m]]  |
 +|[[:en:zubehoer#Extended_connection_cable_for_the_s88-feedback_bus|Kabel s88 2m]]  |
 +^**s88-connection according to {{:de:cad:s88n_250.gif?50x34}} with 2 RJ-45 plugs, blue cable, screened.**|
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 0,5m]]  |
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 1m]]  |
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 2m]]  |
 +|[[:en:zubehoer#Connection_cable_for_s88-connections_according-to_s88-n|Kabel Patch 3m]]  |
 +
 +Subject to technical changes and errors.\\
 +© 2017 by LDT\\  [[:en:rm-88-n-o#rm-88-n-o|{{  :de:images:zurueck_en_page.png?40x32}}]]
 