Unterschiede
Hier werden die Unterschiede zwischen zwei Versionen gezeigt.
en:rm-dec-88 [2012/10/09 06:46] ldt_kahrs |
en:rm-dec-88 [2016/08/18 13:41] (current) |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== RM-DEC-88 and RM-DEC-88-O ====== | ====== RM-DEC-88 and RM-DEC-88-O ====== | ||
- | |||
=== 16-fold feedback modules === | === 16-fold feedback modules === | ||
- | |||
== 100% compatible with the s88 from our Digital-Professional-Series ! == | == 100% compatible with the s88 from our Digital-Professional-Series ! == | ||
- | |||
== The feedback modules RM-DEC-88 and RM-DEC-88-O are not anymore available. == | == The feedback modules RM-DEC-88 and RM-DEC-88-O are not anymore available. == | ||
- | + | **Please select the successor modules [[:en:rm-88-n|RM-88-N]] or the [[:en:rm-88-n-o|RM-88-N-O]].** | |
- | Please select the successor modules [[:en:rm-88-n|RM-88-N]] or the [[:en:rm-88-n-o|RM-88-N-O]]. | + | |
{{ :de:foto:rm-dec-88_20_01.jpg }} | {{ :de:foto:rm-dec-88_20_01.jpg }} | ||
- | |||
==== RM-DEC-88 Opto and RM-DEC-88 for MEMORY, INTERFACE and Intellibox / TWIN-CENTER with 75cm connection cable. ==== | ==== RM-DEC-88 Opto and RM-DEC-88 for MEMORY, INTERFACE and Intellibox / TWIN-CENTER with 75cm connection cable. ==== | ||
- | |||
====== Features of the RM-DEC-88 and RM-DEC-88-O ====== | ====== Features of the RM-DEC-88 and RM-DEC-88-O ====== | ||
- | |||
* For connection to: **INTERFACE** (up to 31 modules), **MEMORY** (up to 3 modules), **Intellibox**/**TWIN-CENTER** (up to 31 modules) and our **High Speed Interface HSI-88** (up to 31 modules). | * For connection to: **INTERFACE** (up to 31 modules), **MEMORY** (up to 3 modules), **Intellibox**/**TWIN-CENTER** (up to 31 modules) and our **High Speed Interface HSI-88** (up to 31 modules). | ||
* The feedback modules **RM-DEC-88** and **RM-DEC-88 Opto** can be combined with the s88 feedback modules from **Märklin** and other manufacturers as required. | * The feedback modules **RM-DEC-88** and **RM-DEC-88 Opto** can be combined with the s88 feedback modules from **Märklin** and other manufacturers as required. | ||
- | * **Simple and secure** connection of switch rails, contact rails, occupancy sensors or reed-contacts by **screw clips.** | + | * **Simple and secure** connection of switch rails, contact rails, occupancy sensors or reed-contacts by **screw clips.** |
* The **RM-DEC-88 Opto** is equipped with additional **opto coupler** and therefore **extremely** protected **against interference**. | * The **RM-DEC-88 Opto** is equipped with additional **opto coupler** and therefore **extremely** protected **against interference**. | ||
- | * Our feedback modules **RM-DEC-88** and **RM-DEC-88 Opto** from our **Digital-Professional-Series** can be operated without any difficulty from your digitally controlled model railroad as these decoders are **100% compatible** with the feedback module **s88**. | + | * Our feedback modules **RM-DEC-88** and **RM-DEC-88 Opto** from our **Digital-Professional-Series** can be operated without any difficulty from your digitally controlled model railroad as these decoders are **100% compatible** with the feedback module **s88**. |
* Suitable installation material can be ordered under: [[:en:zubehoer|accessories]]. | * Suitable installation material can be ordered under: [[:en:zubehoer|accessories]]. | ||
- | |||
== From the table below you can see which feedback module may be used with the contacts of your model railroad: == | == From the table below you can see which feedback module may be used with the contacts of your model railroad: == | ||
- | + | ^Kind of contacts ^ RM-DEC-88 ^ RM-DEC-88 Opto | | |
- | ^Kind of contacts ^RM-DEC-88 ^RM-DEC-88 Opto | | + | |
^**Circuit-track(3-conductor rail system) ** | X | X | | ^**Circuit-track(3-conductor rail system) ** | X | X | | ||
^**Contact-track (3-conductor rail system) ** | X | X | | ^**Contact-track (3-conductor rail system) ** | X | X | | ||
^**Reed-contact, Occupancy detector with relay output \\ (2-conductor and 3-conductor rail system) ** | X | X | | ^**Reed-contact, Occupancy detector with relay output \\ (2-conductor and 3-conductor rail system) ** | X | X | | ||
^**Track contact-switch (2-conductor rail system) ** | X | | | ^**Track contact-switch (2-conductor rail system) ** | X | | | ||
- | ^**Connection cable between contacts and feedback module \\ more than 2 meters (2-conductor and 3-conductor rail system) ** | X | | | + | ^**Connection cable between contacts and feedback module \\ more than 2 meters (2-conductor and 3-conductor rail system) ** | X | |
- | ^**Occupancy detector on a 2-conductor rail system (with additional module \\ see description below) Better to use our octal feedback module with \\ integrated occupancy detection (RM-GB-8-N). ** | X | | | + | ^**Occupancy detector on a 2-conductor rail system \\ (with additional module see description below) \\ Better to use our octal feedback module with \\ integrated occupancy detection (RM-GB-8-N). ** | X | | |
- | ^**Turnout-feedback (with additional module- see description below) ** | X | | \\ | + | ^**Turnout-feedback (with additional module- \\ see description below) ** | X | | \\ |
- | * **Track occupancy detection at two-rail 2-conductor systems:** Contrary to the Märklin 3-conductor rail-system can the occupancy of direct-current rails only be reliably realized with electronic circuitry which measure the current at the track section. For this application is it **recommended to use our 8-fold feedback module with integrated track occupancy monitor** ([[:en:rm-gb-8-n|RM-GB-8-N]] ). In case you integrated already some occupancy circuits you can combine those with our **feedback modules RM-DEC-88-Opto** provided that the occupancy circuits have no potential-free outputs. Four of such modules can be connected directly to a feedback module **RM-DEC-88-Opto** and report the occupancy situation of 16 track sections to the control unit. If the occupancy monitor has potential-free report outputs (e.g. relay contacts) you can apply our feedback module **RM-DEC-88**. | + | * **Track occupancy detection at two-rail 2-conductor systems:** Contrary to the Märklin 3-conductor rail-system can the occupancy of direct-current rails only be reliably realized with electronic circuitry which measure the current at the track section. For this application is it **recommended to use our 8-fold feedback module with integrated track occupancy monitor** ([[:en:rm-gb-8-n|RM-GB-8-N]] ). In case you integrated already some occupancy circuits you can combine those with our **feedback modules RM-DEC-88-Opto** provided that the occupancy circuits have no potential-free outputs. Four of such modules can be connected directly to a feedback module **RM-DEC-88-Opto** and report the occupancy situation of 16 track sections to the control unit. If the occupancy monitor has potential-free report outputs (e.g. relay contacts) you can apply our feedback module **RM-DEC-88**. |
- | * **Feedback from turnouts:** If you require the feedback of the actual turnout position to the control unit (or personal computer) you can apply our feedback module **RM-DEC-88-Opto**. For further information please attend to our description under [[:en:dl_ldt_old|Feedback of the turnout position]]. | + | |
- | * **Extended connection cable:** All LDT feedback modules will be supplied ex factory together with a 75 cm interference protected, twisted s88-bus cable. | + | |
+ | * **Feedback from turnouts:** If you require the feedback of the actual turnout position to the control unit (or personal computer) you can apply our feedback module **RM-DEC-88-Opto**. For further information please attend to our description under [[:en:dl_rm-dec-88-o_nml|Feedback of the turnout position]]. | ||
+ | |||
+ | * **Extended connection cable:** All LDT feedback modules will be supplied ex factory together with a 75 cm interference protected, twisted s88-bus cable. | ||
== Additionally we offer connection cables at low cost: == | == Additionally we offer connection cables at low cost: == | ||
- | ^**ss88-standard connection with 2 original s88-plugs, \\ | + | ^**s88-standard connection with 2 original s88-plugs, \\ gray cable, twisted, round. Plus pin bar for bus extension.** | |
- | gray cable, twisted, round. Plus pin bar for bus extension.** | | + | |
|[[:en:zubehoer#Extended connection cable for the s88-feedback bus|Kabel s88 0,5m]] | | |[[:en:zubehoer#Extended connection cable for the s88-feedback bus|Kabel s88 0,5m]] | | ||
|[[:en:zubehoer#Extended connection cable for the s88-feedback bus|Kabel s88 1m]] | | |[[:en:zubehoer#Extended connection cable for the s88-feedback bus|Kabel s88 1m]] | | ||
|[[:en:zubehoer#Extended connection cable for the s88-feedback bus|Kabel s88 2m]] | | |[[:en:zubehoer#Extended connection cable for the s88-feedback bus|Kabel s88 2m]] | | ||
- | |||
====== Downloads ====== | ====== Downloads ====== | ||
- | |||
Instructions regarding this not anymore available article can be found here: [[:en:dl_ldt_old|Downloads RM-DEC-88 and RM-DEC-88-O]].\\ Instructions for all LDT-Components can be found here: [[:en:downloads|Übersicht Downloads]]. | Instructions regarding this not anymore available article can be found here: [[:en:dl_ldt_old|Downloads RM-DEC-88 and RM-DEC-88-O]].\\ Instructions for all LDT-Components can be found here: [[:en:downloads|Übersicht Downloads]]. | ||
- | |||
====== Sample-Connections ====== | ====== Sample-Connections ====== | ||
- | |||
Sample-connections regarding this not anymore available article can be found here:\\ [[:en:ab_nml|Sample-Connections RM-DEC-88 and RM-DEC-88-O]]. \\ Sample-connections for all LDT-Components can be found here: [[:en:anschlussbeispiele|Overview Sample-Connections]]. | Sample-connections regarding this not anymore available article can be found here:\\ [[:en:ab_nml|Sample-Connections RM-DEC-88 and RM-DEC-88-O]]. \\ Sample-connections for all LDT-Components can be found here: [[:en:anschlussbeispiele|Overview Sample-Connections]]. | ||
- | + | Subject to technical changes and errors. \\ © 2016 by LDT \\ [[:en:rm-dec-88#rm-dec-88_and_rm-dec-88-o|{{ :de:images:zurueck_en_page.png?40x32}}]] | |
- | Subject to technical changes and errors. \\ © 2012 by LDT \\ [[:en:rm-dec-88#rm-dec-88_and_rm-dec-88-o|{{ :de:images:zurueck_en_page.png?40x32}}]] | + | |
\\ | \\ | ||
- |