Sample-Connections: Feedback modules with integrated occupancy detectors RM-GB-8-N

> To overview: sample connections sorted by digital command stations
> To overview: sample connections sorted by digital components
> To product description: RM-GB-8-N
> To product selection: s88-feedback bus

description file edition
General (3-rail conductor):
Combinations of s88-standard connections and bus connections according
to s88-N via patch cable
page_1782 04/2020
Occupancy feedback test with model railway indecandescent lamps page_1441 04/2020
Track monitoring via isolated center conductor page_1342 04/2020
Track section monitoring and switching off (voltage free) page_1344 03/2022
Equivalent current at monitored and non-monitored areas page_1346 04/2020
Combine existing RM-GB-8 with RM-GB-8-N (1) page_1120 04/2020
Combine existing RM-GB-8 with RM-GB-8-N (2) page_1121 04/2020
General (2-rail conductor):
Combinations of s88-standard connections and bus connections according
to s88-N via patch cable
page_1782 04/2020
Occupancy feedback test with model railway indecandescent lamps page_1441 04/2020
Track monitoring with one isolated rail page_1276 04/2020
Track section monitoring and switching off (voltage free) page_592 03/2022
Monitoring of slow-down and stop-sections and common switching off
(voltage free)
page_614 03/2022
Equivalent current at monitored and non-monitored areas page_615 04/2020
Increasing the minimum response current on large- and garden model layouts page_1931 08/2021
Combine existing RM-GB-8 with RM-GB-8-N (1) page_1120 04/2020
Combine existing RM-GB-8 with RM-GB-8-N (2) page_1121 04/2020
HSI-88-USB (3-rail conductor):
Track monitoring via isolated center conductor / s88 standard cable page_958 04/2020
Track monitoring via isolated center conductor / patch-cable to s88-N page_1148 04/2020
Track section monitoring with total isolated track / s88 standard cable page_959 04/2020
Track section monitoring with total isolated track / patch-cable to s88-N page_1149 04/2020
HSI-88-USB (2-rail conductor):
Track occupancy feedback with one isolated rail / s88 standard cable page_956 04/2020
Track occupancy feedback with one isolated rail / patch-cable to s88-N page_1146 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_957 04/2020
Track occupancy feedback with two isolated rails / patch-cable to s88-N page_1147 04/2020
HSI-88 (3-rail conductor):
Track monitoring via isolated center conductor / s88 standard cable page_1237 04/2020
Track monitoring via isolated center conductor / patch-cable to s88-N page_1238 04/2020
Track section monitoring with total isolated track / s88 standard cable page_1239 04/2020
Track section monitoring with total isolated track / patch-cable to s88-N page_1240 04/2020
HSI-88 (2-rail conductor):
Track occupancy feedback with one isolated rail / s88 standard cable page_1233 04/2020
Track occupancy feedback with one isolated rail / patch-cable to s88-N page_1234 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_1235 04/2020
Track occupancy feedback with two isolated rails / patch-cable to s88-N page_1236 04/2020
Central Station 3 (Märklin 60226) / Märklin-Digital (3-rail conductor):
Track monitoring with isolated center conductor / patch-cable to s88-N page_1796 04/2020
Track monitoring with total isolated track / patch-cable to s88-N page_1797 04/2020
Track monitoring with two booster current circuits (with DB-4) /
patch-cable to s88-N
page_1798 04/2020
Feedback modules RM-GB-8-N on Märklin S88 LINK page_1886 04/2020
Central Station 3 (Märklin 60226) / DCC (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
patch-cable to s88-N
page_1750 04/2020
Track occupancy feedback with one isolated rail / patch-cable to s88-N page_1752 04/2020
Track occupancy feedback with two isolated rails / patch-cable to s88-N page_1753 04/2020
Occupancy detection at a reversing loop with KSM-SG / patch-cable to s88-N page_1754 04/2020
Feedback modules RM-GB-8-N on Märklin S88 LINK page_1886 04/2020
Accelerated feedback via HSI-88 / patch-cable to s88-N page_1730 04/2020
Accelerated feedback via HSI-88-USB / patch-cable to s88-N page_1729 04/2020
Central Station 3 plus (Märklin 60216) / Märklin-Digital (3-rail conductor):
Feedback modules RM-GB-8-N on Märklin S88 LINK page_1889 04/2020
Central Station 3 plus (Märklin 60216) / DCC (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
patch-cable to s88-N
page_1751 04/2020
Track occupancy feedback with one isolated rail / patch-cable to s88-N page_1755 04/2020
Track occupancy feedback with two isolated rails / patch-cable to s88-N page_1756 04/2020
Occupancy detection at a reversing loop with KSM-SG / patch-cable to s88-N page_1757 04/2020
Feedback modules RM-GB-8-N on Märklin S88 LINK page_1889 04/2020
Accelerated feedback via HSI-88 / patch-cable to s88-N page_1734 04/2020
Accelerated feedback via HSI-88-USB / patch-cable to s88-N page_1733 04/2020
Central Station 2 (Märklin 60213/60214/60215) / Märklin-Digital (3-rail conductor):
Track monitoring with isolated center conductor / s88 standard cable page_647 04/2020
Track monitoring with total isolated track / s88 standard cable page_648 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_649 04/2020
Feedback modules RM-GB-8-N on Märklin S88 LINK page_1892 04/2020
Central Station 2 (Märklin 60214/60215) / DCC (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_1021 04/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_1022 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_1023 04/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_1024 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_1025 04/2020
Feedback modules RM-GB-8-N on Märklin S88 LINK page_1892 04/2020
Accelerated feedback via HSI-88 / patch-cable to s88-N page_1028 04/2020
Accelerated feedback via HSI-88-USB / patch-cable to s88-N page_1030 04/2020
Numbering the feedback registrations / s88 standard cable page_1032 04/2020
Numbering the feedback registrations / patch-cable to s88-N page_1033 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_1034 04/2020
Central Station 1 (Märklin 60212 as well as with ESU Upgrade 'Reloaded') /
Märklin-Digital (3-rail conductor):
Track monitoring with isolated center conductor / s88 standard cable page_634 04/2020
Track monitoring with total isolated track / s88 standard cable page_635 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_636 04/2020
Central Station 1 (Märklin 60212 with ESU Upgrade 'Reloaded') /
DCC (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_1003 04/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_1004 04/2020
Shuttle train line with one isolated rail / s88 standard cable page_1005 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_1006 04/2020
Shuttle train line with two isolated rails / s88 standard cable page_1007 04/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_1008 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_1009 04/2020
Accelerated feedback via HSI-88 / s88 standard cable page_1012 04/2020
Accelerated feedback via HSI-88-USB / s88 standard cable page_1013 04/2020
Numbering the feedback registrations / s88 standard cable page_1014 04/2020
Numbering the feedback registrations / patch-cable to s88-N page_1015 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_1016 04/2020
Control Unit (6021) Märklin-Digital (3-rail conductor):
Track monitoring with isolated center conductor / s88 standard cable page_618 04/2020
Track monitoring with total isolated track / s88 standard cable page_619 04/2020
Numbering the feedback registrations / s88 standard cable page_907 04/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_913 04/2020
Numbering the feedback registrations at the Interface (various feedback
modules) / s88 standard cable
page_586 04/2020
Track monitoring with two booster current circuit (with DB-2) /
s88 standard cable
page_623 04/2020
Track monitoring with two booster current circuit (with Booster 6015) /
s88 standard cable
page_622 04/2020
Intellibox (3-rail conductor):
Track monitoring via isolated center conductor / s88 standard cable page_616 04/2020
Track section monitoring with total isolated track / s88 standard cable page_617 04/2020
Numbering the feedback registrations / s88 standard cable page_905 04/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_911 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_584 04/2020
Track monitoring with two booster current circuit (with DB-2) /
s88 standard cable
page_624 04/2020
Track monitoring with two booster current circuit (with Power 3) /
s88 standard cable
page_621 04/2020
Intellibox (2-rail conductor):
Track occupancy feedback with one isolated rail / s88 standard cable page_590 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_591 04/2020
Numbering the feedback registrations / s88 standard cable page_905 04/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_911 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_584 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_600 04/2020
Track monitoring with two booster current circuits (with Power 3) /
s88 standard cable
page_595 04/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_551 04/2020
Intellibox II (3-rail conductor):
Track monitoring via isolated center conductor / s88 standard cable page_1307 04/2020
Track section monitoring with total isolated track / s88 standard cable page_1308 04/2020
Numbering the feedback registrations / s88 standard cable page_1315 04/2020
Numbering the feedback registrations / patch-cable to s88-N page_1316 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_1317 04/2020
Track monitoring with two booster current circuit (with DB-2) /
s88 standard cable
page_1309 04/2020
Track monitoring with two booster current circuit (with Power 3) /
s88 standard cable
page_1310 04/2020
Intellibox II (2-rail conductor):
Track occupancy feedback with one isolated rail / s88 standard cable page_1327 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_1328 04/2020
Numbering the feedback registrations / s88 standard cable page_1315 04/2020
Numbering the feedback registrations / patch-cable to s88-N page_1316 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_1317 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_1330 04/2020
Track monitoring with two booster current circuits (with Power 3) /
s88 standard cable
page_1331 04/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_1329 04/2020
TWIN-CENTER (2-rail conductor):
Track monitoring with one isolated rail / s88 standard cable page_593 04/2020
Track monitoring with two isolated rails / s88 standard cable page_594 04/2020
Numbering the feedback registrations / s88 standard cable page_906 04/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_912 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_585 04/2020
Track monitoring with two booster current circuit (with DB-2) /
s88 standard cable
page_599 04/2020
Track monitoring with two booster current circuit (with TWIN-BOOSTER) /
s88 standard cable
page_596 04/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_598 04/2020
EasyControl (3-rail conductor):
Supply to monitored track sections (track occupancy feedback) /
s88 standard cable
page_559 04/2020
Track monitoring via isolated center conductor / s88 standard cable page_625 04/2020
Track section monitoring with total isolated track / s88 standard cable page_626 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_627 04/2020
Numbering the feedback registrations / s88 standard cable page_908 04/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_914 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_587 04/2020
EasyControl (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_555 04/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_601 04/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_602 04/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_603 04/2020
Numbering the feedback registrations / s88 standard cable page_908 04/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_914 04/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_587 04/2020
Digicentral DR5000 (2-rail conductor):
Supply to monitored track sections (track occupancy feedback)
(with DB-4) / patch-cable to s88-N
page_1941 05/2022
Track occupancy feedback with one isolated rail (with DB-4) /
patch-cable to s88-N
page_1943 05/2022
Track occupancy feedback with two isolated rails (with DB-4) /
patch-cable to s88-N
page_1945 05/2022
Track monitoring with two booster current circuits (with DB-4) /
patch-cable to s88-N
page_1946 05/2022
RedBox (3-rail conductor):
Supply to monitored track sections (track occupancy feedback)
(with DB-2) / patch-cable to s88-N
page_1803 04/2020
Supply to monitored track sections (track occupancy feedback)
(with DB-4) / patch-cable to s88-N
page_1804 04/2020
Track monitoring via isolated center conductor (with DB-2) /
patch-cable to s88-N
page_1805 04/2020
Track monitoring via isolated center conductor (with DB-4) /
patch-cable to s88-N
page_1806 04/2020
Track section monitoring with total isolated track (with DB-2) /
patch-cable to s88-N
page_1807 04/2020
Track section monitoring with total isolated track (with DB-4) /
patch-cable to s88-N
page_1808 04/2020
Track monitoring with two booster current circuits (with DB-2) /
patch-cable to s88-N
page_1809 04/2020
Track monitoring with two booster current circuits (with DB-4) /
patch-cable to s88-N
page_1810 04/2020
Numbering the feedback registrations (RM-GB-8-N) /
patch-cable to s88-N
page_1829 04/2020
Numbering the feedback registrations (various feedback modules) /
patch-cable to s88-N
page_1830 04/2020
RedBox (2-rail conductor):
Supply to monitored track sections (track occupancy feedback)
(with DB-2) / patch-cable to s88-N
page_1846 04/2020
Supply to monitored track sections (track occupancy feedback)
(with DB-4) / patch-cable to s88-N
page_1847 04/2020
Track occupancy feedback with one isolated rail (with DB-2) /
patch-cable to s88-N
page_1848 04/2020
Track occupancy feedback with one isolated rail (with DB-4) /
patch-cable to s88-N
page_1849 04/2020
Track occupancy feedback with two isolated rails (with DB-2) /
patch-cable to s88-N
page_1850 04/2020
Track occupancy feedback with two isolated rails (with DB-4) /
patch-cable to s88-N
page_1851 04/2020
Track monitoring with two booster current circuits (with DB-2) /
patch-cable to s88-N
page_1852 04/2020
Track monitoring with two booster current circuits (with DB-4) /
patch-cable to s88-N
page_1853 04/2020
Numbering the feedback registrations (RM-GB-8-N) /
patch-cable to s88-N
page_1829 04/2020
Numbering the feedback registrations (various feedback modules) /
patch-cable to s88-N
page_1830 04/2020
ECoS 2 (50200) (3-rail conductor):
Supply to monitored track sections (track occupancy feedback) /
s88 standard cable
page_1073 05/2020
Track monitoring via isolated center conductor / s88 standard cable page_1084 05/2020
Track section monitoring with total isolated track / s88 standard cable page_1085 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_1086 05/2020
Numbering the feedback registrations / s88 standard cable page_1102 05/2020
Numbering the feedback registrations / patch-cable to s88-N page_1103 05/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_1077 05/2020
ECoS 2 (50200) (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_1072 05/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_1078 05/2020
Shuttle train line with one isolated rail / s88 standard cable page_1082 05/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_1079 05/2020
Shuttle train line with two isolated rails / s88 standard cable page_1083 05/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_1080 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_1081 05/2020
Numbering the feedback registrations / s88 standard cable page_1102 05/2020
Numbering the feedback registrations / patch-cable to s88-N page_1103 05/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_1077 05/2020
ECoS 1 (50000) (3-rail conductor):
Supply to monitored track sections (track occupancy feedback) /
s88 standard cable
page_560 05/2020
Track monitoring via isolated center conductor / s88 standard cable page_628 05/2020
Track section monitoring with total isolated track / s88 standard cable page_629 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_630 05/2020
Numbering the feedback registrations / s88 standard cable page_909 05/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_915 05/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_588 05/2020
ECoS 1 (50000) (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_556 05/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_604 05/2020
Shuttle train line with one isolated rail / s88 standard cable page_612 05/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_605 05/2020
Shuttle train line with two isolated rails / s88 standard cable page_613 05/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_606 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_607 05/2020
Numbering the feedback registrations / s88 standard cable page_909 05/2020
Numbering the feedback registrations (RM-GB-8-N) / patch-cable to s88-N page_915 05/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_588 05/2020
Commander (3-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_980 05/2020
Track monitoring via isolated center conductor / s88 standard cable page_996 05/2020
Track section monitoring with total isolated track / s88 standard cable page_997 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_998 05/2020
Numbering the feedback registrations / s88 standard cable page_991 05/2020
Numbering the feedback registrations / patch-cable to s88-N page_992 05/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_990 05/2020
Commander (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_975 05/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_993 05/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_994 05/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_989 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_995 05/2020
Numbering the feedback registrations / s88 standard cable page_991 05/2020
Numbering the feedback registrations / patch-cable to s88-N page_992 05/2020
Numbering the feedback registrations (various feedback modules) /
s88 standard cable
page_990 05/2020
DiCoStation (3-rail conductor):
Supply to monitored track sections (track occupancy feedback) /
patch-cable to s88-N (with DB-2)
page_1184 05/2020
Supply to monitored track sections (track occupancy feedback) /
patch-cable to s88-N (with DB-4)
page_1641 05/2020
Supply to monitored track sections (track occupancy feedback) /
s88 standard cable
page_561 05/2020
Track monitoring via isolated center conductor /
patch-cable to s88-N (with DB-2)
page_1573 05/2020
Track monitoring via isolated center conductor /
patch-cable to s88-N (with DB-4)
page_1642 05/2020
Track monitoring via isolated center conductor / s88 standard cable page_631 05/2020
Track section monitoring with total isolated track /
patch-cable to s88-N (with DB-2)
page_1574 05/2020
Track section monitoring with total isolated track /
patch-cable to s88-N (with DB-4)
page_1643 05/2020
Track section monitoring with total isolated track / s88 standard cable page_632 05/2020
Track monitoring with two booster current circuits (with DB-2) /
patch-cable to s88-N
page_1575 05/2020
Track monitoring with two booster current circuits (with DB-4) /
patch-cable to s88-N
page_1644 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_633 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
patch-cable to s88-N (with DB-2)
page_916 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
patch-cable according to s88-N (with DB-4)
page_1630 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
s88 standard cable (with DB-2)
page_910 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
s88 standard cable (with DB-4)
page_1629 05/2020
Numbering the feedback registrations (various feedback modules)
(with DB-2) / patch-cable to s88-N
page_589 05/2020
Numbering the feedback registrations (various feedback modules)
(with DB-4) / patch-cable to s88-N
page_1631 05/2020
DiCoStation (2-rail conductor):
Supply of monitored track sections (track occupancy feedback) /
patch-cable to s88-N (with DB-2)
page_1183 05/2020
Supply of monitored track sections (track occupancy feedback) /
patch-cable to s88-N (with DB-4)
page_1622 05/2020
Supply of monitored track sections (track occupancy feedback) /
s88 standard cable
page_557 05/2020
Track occupancy feedback with one isolated rail /
patch-cable to s88-N (with DB-2)
page_1564 05/2020
Track occupancy feedback with one isolated rail /
patch-cable to s88-N (with DB-4)
page_1623 05/2020
Track occupancy feedback with one isolated rail / s88 standard cable page_608 05/2020
Track occupancy feedback with two isolated rails /
patch-cable to s88-N (with DB-2)
page_1565 05/2020
Track occupancy feedback with two isolated rails /
patch-cable to s88-N (with DB-4)
page_1624 05/2020
Track occupancy feedback with two isolated rails / s88 standard cable page_609 05/2020
Occupancy detection at a reversing loop with KSM-SG /
patch-cable to s88-N (with DB-2)
page_1566 05/2020
Occupancy detection at a reversing loop with KSM-SG /
patch-cable to s88-N (with DB-4)
page_1625 05/2020
Occupancy detection at a reversing loop with KSM-SG / s88 standard cable page_610 05/2020
Track monitoring with two booster current circuits (with DB-2) /
patch-cable to s88-N
page_1567 05/2020
Track monitoring with two booster current circuits (with DB-4) /
patch-cable to s88-N
page_1626 05/2020
Track monitoring with two booster current circuits (with DB-2) /
s88 standard cable
page_611 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
patch-cable to s88-N (with DB-2)
page_916 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
patch-cable according to s88-N (with DB-4)
page_1630 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
s88 standard cable (with DB-2)
page_910 05/2020
Numbering the feedback registrations (RM-GB-8-N) /
s88 standard cable (with DB-4)
page_1629 05/2020
Numbering the feedback registrations (various feedback modules)
(with DB-2) / patch-cable to s88-N
page_589 05/2020
Numbering the feedback registrations (various feedback modules)
(with DB-4) / patch-cable to s88-N
page_1631 05/2020

Subject to technical changes and errors.
© 2022 by LDT
Märklin and Motorola are registered trade marks.